e-mail:iecmktg@vsnl.com

 

   Kirloskar Electric Motors :  


The rated output, listed CDF and total inertia are closely interlinked and alteration of any one of them has an effect on the other two.

The driven inertia has an effect of increased heating with the increasing number of starts/hour and therefore the inertia values given should not be exceeded in these cases. 

However, the permissible load inertia can be increased by lowering the number of starts as per the following rules.

For the starting class lower than 150 or between two listed categories, the “total permissible inertia” (i.e. motor + load + coupling + brake drum) can be varied in inverse proportion to the number of starts.

BEARING & LUBRICATION 
BEARING CHART AND LUBRICATION DETAILS FOR CAGE & SLIPRING MOTORS

 

 

Bearing
Number

Grease
Quantity

Lubrication Intervals in Hours
Sr.
No.
Frame DE side NDE
Side
In Grams 4 Pole 6 Pole 8 Pole
1 80 6204 6204 3 11,000 17,000 20,000
2 90 6205 6205 3.7 10,000 16,000 20,000
3 100 6206 6206 4.7 9,000 14,000 19,000
4 112 6306 6206 6.5 8,000 12,000 18,000
5 132 6308 6208 9.8 6,500 10,000 14,000
6 160 6309 6209 11.8 6,000 9,000 13,000
7 180 6310 6309 15 4,000 1,500 4,000
8 200 6312 6310 20 4,000 1,500 4,000
9 ID 132M 6308 6308 10 6,500 10,000 14,000
10 ID160M/L 6309 6309 12 6,000 9,000 13,000
11 ID 180L 6310 6310 15 4,000 1,500 4,000
12 ID 200L 6312 6312 20 4,000 1,500 4,000
13 ID 225M 6313 6313 20 4000 1,500 4,000

Note : Grease specification : Multipurpose grease conforming to grade 3 of IS 7623.

Back

Next

The Indian Electric Co. 
Bharat Bhavan,1360 Shukrawar Peth, Natu Baug,Pune - 411 002 (India)
Tel. :
020-24474303, 24473038, 24471586, 24475845.
Tel. Direct Mkt. :
020-24482491, 24473711, 24478581, 24470288.
Fax No. :
020-24473037, 020-24470807.
e-mail :
iecmktg@vsnl.com
Website : www.indianelectric.com

About Us | Products | Services | Stock | FAQs 
Feedback | Search | Contact Us|Home